Tridonic - Battery Backup Ballast

Set Descending Direction
View as List Grid

7 Items

per page
  1. Tridonic 89899611 EM-14B-BASIC Emergency lighting supply unit
    EM-14B-BASIC
    $34.01

    Tridonic : 89899611 - EM BASIC, 230 – 240 V 50/60 Hz Spec SheetTridonic 89899611 - EM BASIC, 230 – 240 V 50/60 Hz Spec Sheet

    Product description • Emergency lighting supply unit for manual testing • For linear and compact fluorescent lamps • Small dimensions (28 x 39 mm cross-section) • 5-year guarantee Properties • 1or 3 h rated duration • Compatible with all electronic ballasts (dimmable and non-dimmable) • Can also be used in combination with conventional magnetic ballasts • 5-pole technology: 4-pole lamp changeover and delayed power switching for the ballast • Optimised AC output voltage for TC-DD and TC-L lamps • Optimised DC output voltage for T8 lamps • Cathode heating adapted for compact lamps • Switchover relay with high-current contacts • IDC (insulation displacement connection) • Green charge status display LED • Checking the emergency lighting function by interrupting the unswitched phase • Optional test switch • Deep discharge protection • Battery connection, short-circuit protected (not reversible) • No polarity reversal protection for battery Batteries • High-temperature cells • NiCd batteries • D or Cs cells • Blade terminals for simple connection • 4-year design life • 1-year guarantee • For battery compatibility refer to chapter Ballast-Lumen-Factor (BLF)

    Learn More
  2. EM-34B-BASIC
    EM-34B-BASIC
    $35.20

    Tridonic : 89818662 - EM BASIC, 230 – 240 V 50/60 Hz Spec SheetTridonic 89818662 EM-34B-BASIC Spec Sheet

    Emergency lighting supply unit for manual testing - For linear and compact fluorescent lamps - Small dimensions (28 x 39 mm cross-section) - 5-year guarantee Properties - 1 or 3 h rated duration - Compatible with all electronic ballasts (dimmable and nondimmable) - Can also be used in combination with conventional magnetic ballasts - 5-pole technology: 4-pole lamp changeover and delayed power switching for the ballast - Optimised AC output voltage for TC-DD and TC-L lamps - Optimised DC output voltage for T8 lamps - Cathode heating adapted for compact lamps - Switchover relay with high-current contacts - IDC (insulation displacement connection) - Green charge status display LED - Checking the emergency lighting function by interrupting the unswitched phase - Optional test switch - Deep discharge protection - Battery connection, short-circuit protected (not reversible) - Polarity reversal protection for battery Batteries - High-temperature cells - NiCd batteries - D or Cs cells - Blade terminals for simple connection - 4-year design life - 1-year guarantee - For battery compatibility refer to datasheet

    Learn More
  3. Tridonic EM-34C-BASIC 89800107 Emergency Lighting Supply Unit for Manual Testing
    EM-34C-BASIC
    $35.63

    TRIDONIC-EM-34C-BASIC 89800107 Spec SheetTRIDONIC-EM-34C-BASIC-89800107-Spec-Sheet

    Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions -28 x 39 mm cross-section- 5-year guarantee 1 or 3 h rated duration Compatible with all electronic ballasts dimmable and nondimmable Can also be used in combination with conventional magnetic ballasts 5-pole technology 4-pole lamp changeover and delayed power switching for the ballast Optimised AC output voltage for TC-DD and TC-L lamps Optimised DC output voltage for T8 lamps Cathode heating adapted for compact lamps

    Learn More
  4. Tridonic EM-35A-BASIC 89818581Emergency Lighting Supply Unit for Manual Testing
    EM-35A-BASIC
    $40.63

    TRIDONIC-EM-35A-BASIC 89818581-Spec-SheetTRIDONIC EM-35A-BASIC 89818581 Spec Sheet

    Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions 28 x 39 mm cross-section 5-year guarantee 1 or 3 h rated duration Compatible with all electronic ballasts dimmable and nondimmable Can also be used in combination with conventional magnetic ballasts

    Learn More
  5. Tridonic LC-35/150-700-NOTE02 87500683 Emergency Lighting Supply Unit for Manual Testing
    LC-35-150-700-NOTE02
    $41.88

    TRIDONIC-LC-35-150-700-NOTE02 87500683 Spec-SheetTRIDONIC LC-35-150-700-NOTE02 87500683 Spec-Sheet

    Emergency lighting supply unit for manual testing For linear and compact fluorescent lamps Small dimensions 28 x 39 mm cross-section 5-year guarantee 1 or 3 h rated duration Compatible with all electronic ballasts dimmable and nondimmable Can also be used in combination with conventional magnetic ballasts

    Learn More
  6. Tridonic PC-2x26-4-TC-COMBO 89899930 Electronic Ballast and Emergency Lighting
    PC-2x26-4-TC-COMBO
    $53.69

    TRIDONIC-PC-2x26-4-TC-COMBO-89899930-Spec-SheetTRIDONIC PC-2x26-4-TC-COMBO 89899930 Spec-Sheet

    Combination of electronic ballast and emergency lighting unit For compact fluorescent lamps For manual testing of the emergency lighting function 5-year guarantee Lightweight one-part emergency lighting unit Simple wiring No compatibility problems 3 h rated duration for TC-DD lamp variants 1 and 3 h rated duration for TC-D-T lamp variants Selectable operating time - jumper Lamp warm start in normal operation

    Learn More
  7. Tridonic 89805268 PC-2x36-33-COMBO
    PC-2x36-33-COMBO
    $43.36

    Tridonic 89805268 PC-2x36-33-ComboTridonic 89805268 PC-2x36-33-COMBO Spec Sheet

    Combination of electronic ballast and emergency lighting unit • For T5 and T8 fluorescent lamps • For manual testing of the emergency lighting function • 5-year guarantee Properties • Lightweight one-part emergency lighting unit • For 1, 2, 3 or 4-lamp luminaires • Simple wiring • No compatibility problems • 1or 3 h rated duration • Lamp warm start in normal operation • IDC (insulation displacement connection) • Green charge status display LED • Checking the emergency lighting function by interrupting the unswitched phase • Optional test switch • Electronically controlled battery charging • Deep discharge protection • Short-circuit-proof battery connection • Polarity reversal protection for battery Batteries • High-temperature cells • NiCd or NiMH batteries • D or LA cells • Blade terminals for simple connection • 4-year design life • 1-year guarantee • For battery compatibility refer to chapter „Ballast-Lumen-Factor (BLF)“

    Learn More
Set Descending Direction
View as List Grid

7 Items

per page